Changeset 3000

Show
Ignore:
Timestamp:
05/15/05 12:06:15 (8 years ago)
Author:
khali
Message:

Fix common spelling errors.

Location:
lm-sensors/trunk
Files:
54 modified

Legend:

Unmodified
Added
Removed
  • lm-sensors/trunk/CHANGES

    r2996 r3000  
    6666  Module lm75: Only initialize CMP/INT bit 
    6767  Module lm78: Fix bug with setting negative temperature limits 
    68   Module lm85: Properly differenciate between ADM1027 and ADT7463 
     68  Module lm85: Properly differentiate between ADM1027 and ADT7463 
    6969               Add EMC6D102 support 
    7070  Module lm90: Fix MAX6657, MAX6658 and MAX6659 detection 
  • lm-sensors/trunk/doc/chips/adm1021

    r2134 r3000  
    116116Each sensor has its own low and high limits. When they are crossed, the  
    117117corresponding alarm is set and remains on as long as the temperature stays  
    118 out of range. Temperatures are measured in degrees Celcius. Measurements  
     118out of range. Temperatures are measured in degrees Celsius. Measurements  
    119119are possible between -65 and +127 degrees, with a resolution of one degree. 
    120120 
     
    380380  value, the second number is Low limit value, and the third number is the 
    381381  current temperature. The first two values can be modified. Each value can 
    382   be set and read to full-degree accuracy. All values are in degrees Celcius. 
     382  be set and read to full-degree accuracy. All values are in degrees Celsius. 
    383383  An alarm is issued (usually to a connected ADM9240) when the temperature  
    384384  gets higher then the Overtemperature Shutdown value; it stays on until 
  • lm-sensors/trunk/doc/chips/adm1026

    r1777 r3000  
    5757EEPROM memory on chip. 
    5858 
    59 Temperatures are measured in degrees Celcius.  There are two external 
     59Temperatures are measured in degrees Celsius.  There are two external 
    6060sensor inputs and one internal sensor.  Each sensor has a high and low 
    6161limit.  If the limit is exceeded, an interrupt (#SMBALERT) can be 
  • lm-sensors/trunk/doc/chips/adm1031

    r2573 r3000  
    5252(ADM1030) or two (ADM1031) external diodes. 
    5353 
    54 All temperature values are given in degrees Celcius. Resolution 
     54All temperature values are given in degrees Celsius. Resolution 
    5555is 0.5 degree for the local temperature, 0.125 degree for the remote 
    5656temperatures. 
  • lm-sensors/trunk/doc/chips/adm9240

    r824 r3000  
    5959two FAN rotation speed sensors, VID lines and some miscellaneous stuff. 
    6060 
    61 Temperatures are measured in degrees Celcius. An alarm is triggered whenever 
     61Temperatures are measured in degrees Celsius. An alarm is triggered whenever 
    6262the temperature is above the hot limit, and will continue to be generated 
    6363until the temperature has dropped beneath the hysteresis limit. Measurements 
  • lm-sensors/trunk/doc/chips/asb100

    r2823 r3000  
    4343simply not work (or maybe it will for you... it doesn't for me). 
    4444 
    45 Temperatures are measured and reported in degrees Celcius. 
     45Temperatures are measured and reported in degrees Celsius. 
    4646 
    4747Fan speeds are reported in RPM (rotations per minute).  An alarm is triggered 
  • lm-sensors/trunk/doc/chips/ds1621

    r1145 r3000  
    196196flag. This means, that the "1" tells you that the values in REG_COUNT 
    197197and REG_SLOPE are not valid. "0", on the other hand, means that the 
    198 continous conversion had been stopped long enough to provide valid 
     198continuous conversion had been stopped long enough to provide valid 
    199199readings and that one shot has successfully been fi- red, 
    200200respectively. - Writing accepts "1" to start continuous conversion or 
     
    209209two digits after the radix (decimal point). 
    210210The precise results are only updated if the DONE bit was set, thus you 
    211 have to stop continous conversion early enough prior to reading, 
     211have to stop continuous conversion early enough prior to reading, 
    212212i. e. 1000ms. And, on the other hand, you shouldn't forget to fire off 
    2132131SHOT in order to get the actual temperature rather than that of the 
  • lm-sensors/trunk/doc/chips/fscher

    r2037 r3000  
    5555CPU and auxiliary).  
    5656 
    57 Temperatures are measured in degrees Celcius. The resolution is 1 degree. 
     57Temperatures are measured in degrees Celsius. The resolution is 1 degree. 
    5858 
    5959Fan rotation speeds are reported in RPM (rotations per minute).  
  • lm-sensors/trunk/doc/chips/fscpos

    r1182 r3000  
    4848three fans (power supply, cpu and auxiliary).  
    4949 
    50 Temperatures are measured in degrees Celcius. The resolution is 1 degree. 
     50Temperatures are measured in degrees Celsius. The resolution is 1 degree. 
    5151 
    5252FAN rotation speeds are reported in RPM (rotations per minute).  
  • lm-sensors/trunk/doc/chips/fscscy

    r1760 r3000  
    6060six fans (power supply, cpu and auxiliary).  
    6161 
    62 Temperatures are measured in degrees Celcius. The resolution is 1 degree. 
     62Temperatures are measured in degrees Celsius. The resolution is 1 degree. 
    6363In addition to state and actual temperature, the temperature sensors also export 
    6464a LIMIT temperature for each sensor. The meaning of the information itself is 
     
    107107(value 128) bits used only. If I write 16 or 144 (128+16), it means system 
    108108reset when the counter reaches 0. If I add 32 (for a value of 48 or 176), no 
    109 reset will occure. 
     109reset will occur. 
    110110 
    111111So, the world's simplest watchdog using this mainboard: 
  • lm-sensors/trunk/doc/chips/gl518sm

    r2681 r3000  
    5959computer speakers. 
    6060 
    61 Temperatures are measured in degrees Celcius. An alarm goes off while the 
     61Temperatures are measured in degrees Celsius. An alarm goes off while the 
    6262temperature is above the over temperature limit, and has not yet dropped 
    6363below the hysteresis limit. The alarm always reflects the current situation. 
  • lm-sensors/trunk/doc/chips/gl520sm

    r1736 r3000  
    3838The sensor can report alarms through the computer speakers. 
    3939 
    40 Temperatures are measured in degrees Celcius. An alarm goes off while the 
     40Temperatures are measured in degrees Celsius. An alarm goes off while the 
    4141temperature is above the over temperature limit, and has not yet dropped 
    4242below the hysteresis limit. The alarm always reflects the current situation. 
  • lm-sensors/trunk/doc/chips/it87

    r2914 r3000  
    5656The IT8712F additionally features VID inputs. 
    5757 
    58 Temperatures are measured in degrees Celcius. An alarm is triggered once 
     58Temperatures are measured in degrees Celsius. An alarm is triggered once 
    5959when the Overtemperature Shutdown limit is crossed; it is triggered again 
    6060as soon as it drops below the Hysteresis value. 
  • lm-sensors/trunk/doc/chips/lm63

    r2726 r3000  
    4545and control. 
    4646 
    47 All temperature values are given in degrees Celcius. Resolution is 1.0 
     47All temperature values are given in degrees Celsius. Resolution is 1.0 
    4848degree for the local temperature, 0.125 degree for the remote temperature. 
    4949 
  • lm-sensors/trunk/doc/chips/lm75

    r2965 r3000  
    6666gets higher then the Overtemperature Shutdown value; it stays on until 
    6767the temperature falls below the Hysteresis value. 
    68 All temperatures are in degrees Celcius, and are guaranteed within a  
     68All temperatures are in degrees Celsius, and are guaranteed within a  
    6969range of -55 to +125 degrees. 
    7070 
  • lm-sensors/trunk/doc/chips/lm78

    r746 r3000  
    5959seven voltage sensors, VID lines, alarms, and some miscellaneous stuff. 
    6060 
    61 Temperatures are measured in degrees Celcius. An alarm is triggered once 
     61Temperatures are measured in degrees Celsius. An alarm is triggered once 
    6262when the Overtemperature Shutdown limit is crossed; it is triggered again 
    6363as soon as it drops below the Hysteresis value.  A more useful behaviour  
    64 can be found by setting the Hysteresis value to +127 degrees Celcius; in  
     64can be found by setting the Hysteresis value to +127 degrees Celsius; in  
    6565this case, alarms are issued during all the time when the actual temperature 
    6666is above the Overtemperature Shutdown value. Measurements are guaranteed 
  • lm-sensors/trunk/doc/chips/lm80

    r746 r3000  
    4141seven voltage sensors, alarms, and some miscellaneous stuff. 
    4242 
    43 Temperatures are measured in degrees Celcius. There are two sets of limits 
     43Temperatures are measured in degrees Celsius. There are two sets of limits 
    4444which operate independently. When the HOT Temperature Limit is crossed, 
    4545this will cause an alarm that will be reasserted until the temperature 
  • lm-sensors/trunk/doc/chips/lm83

    r1965 r3000  
    8585north and south bridges, but this couldn't be confirmed. 
    8686 
    87 All temperature values are given in degrees Celcius. Local temperature 
     87All temperature values are given in degrees Celsius. Local temperature 
    8888is given within a range of 0 to +85 degrees. Remote temperatures are 
    8989given within a range of 0 to +125 degrees. Resolution is 1.0 degree, 
  • lm-sensors/trunk/doc/chips/lm87

    r2325 r3000  
    4242miscellaneous stuff. 
    4343 
    44 Temperatures are measured in degrees Celcius. Each input has a high 
     44Temperatures are measured in degrees Celsius. Each input has a high 
    4545and low alarm settings.  A high limit produces an alarm when the value 
    4646goes above it, and an alarm is also produced when the value goes below 
  • lm-sensors/trunk/doc/chips/lm90

    r2955 r3000  
    139139  * Second critical temperature limit 
    140140 
    141 All temperature values are given in degrees Celcius. Resolution 
     141All temperature values are given in degrees Celsius. Resolution 
    142142is 1.0 degree for the local temperature, 0.125 degree for the remote 
    143143temperature. 
  • lm-sensors/trunk/doc/chips/lm92

    r2440 r3000  
    4646 
    4747Each LM92 temperature sensor supports a single temperature sensor. 
    48 Temperatures are exported to proc in degrees celsius * 10000 (in other 
     48Temperatures are exported to proc in degrees Celsius * 10000 (in other 
    4949words temperatures are accurate to 4 decimal places). There are alarms 
    5050for high, low, and critical thresholds. There's also an hysteresis to 
  • lm-sensors/trunk/doc/chips/max1619

    r2564 r3000  
    4040well as the temperature of up to one external diode. 
    4141 
    42 All temperature values are given in degrees Celcius. Resolution 
     42All temperature values are given in degrees Celsius. Resolution 
    4343is 1.0 degree for the local temperature and for the remote temperature. 
    4444 
  • lm-sensors/trunk/doc/chips/pc87360

    r2603 r3000  
    111111---------------------- 
    112112 
    113 Temperatures are reported in degrees Celcius. Each temperature measured has 
     113Temperatures are reported in degrees Celsius. Each temperature measured has 
    114114associated low, high and overtemperature limits, each of which triggers an 
    115115alarm when crossed. 
  • lm-sensors/trunk/doc/chips/sis5595

    r1327 r3000  
    6565If the in4 function is enabled, temp will return 0. 
    6666 
    67 Temperatures are measured in degrees Celcius. An alarm is triggered once 
     67Temperatures are measured in degrees Celsius. An alarm is triggered once 
    6868when the max is crossed; it is also triggered 
    6969when it drops below the min value. 
  • lm-sensors/trunk/doc/chips/thmc50

    r968 r3000  
    4747temperature gets higher then the Overtemperature Shutdown value; it stays on  
    4848until the temperature falls below the Hysteresis value. All temperatures are in  
    49 degrees Celcius, and are guaranteed within a range of -55 to +125 degrees. 
     49degrees Celsius, and are guaranteed within a range of -55 to +125 degrees. 
    5050 
    5151The THMC50 only updates its values each 1.5 seconds; reading it more often 
     
    6666 
    6767temp-os, temp-hyst, and temp are whole degree integers representing degrees 
    68 celcius. 
     68Celsius. 
    6969 
    7070analog_out --   One field: [output-value,rw] 
  • lm-sensors/trunk/doc/chips/via686a

    r2730 r3000  
    4040sensors, five voltage sensors and alarms. 
    4141 
    42 Temperatures are measured in degrees Celcius. An alarm is triggered once 
     42Temperatures are measured in degrees Celsius. An alarm is triggered once 
    4343when the Overtemperature Shutdown limit is crossed; it is triggered again 
    4444as soon as it drops below the hysteresis value.  A more useful behaviour  
    45 can be found by setting the hysteresis value to +127 degrees Celcius; in  
     45can be found by setting the hysteresis value to +127 degrees Celsius; in  
    4646this case, alarms are issued during all the time when the actual temperature 
    4747is above the Overtemperature Shutdown value. Measurements are guaranteed 
  • lm-sensors/trunk/doc/chips/w83781d

    r2569 r3000  
    108108lines, alarms with beep warnings, and some miscellaneous stuff. 
    109109 
    110 Temperatures are measured in degrees Celcius. There is always one main 
     110Temperatures are measured in degrees Celsius. There is always one main 
    111111temperature sensor, and one (W83783S) or two (W83781D and W83782D) other 
    112112sensors.  An alarm is triggered for the main sensor once when the  
    113113Overtemperature Shutdown limit is crossed; it is triggered again as soon as  
    114114it drops below the Hysteresis value. A more useful behaviour  
    115 can be found by setting the Hysteresis value to +127 degrees Celcius; in  
     115can be found by setting the Hysteresis value to +127 degrees Celsius; in  
    116116this case, alarms are issued during all the time when the actual temperature 
    117117is above the Overtemperature Shutdown value. The driver sets the 
  • lm-sensors/trunk/doc/chips/w83792d

    r2977 r3000  
    3535and Smart Fan II sensors. 
    3636 
    37 Temperatures are measured in degrees Celcius. There is one main temperature 
     37Temperatures are measured in degrees Celsius. There is one main temperature 
    3838sensor, and two other sensors. A alarm is triggered when the measured 
    3939temperture is higher than the Overtemperature or below the Hysteresis value. 
  • lm-sensors/trunk/doc/chips/w83l785ts

    r2611 r3000  
    4646on several points including this one. 
    4747 
    48 All temperature values are given in degrees Celcius. Resolution 
     48All temperature values are given in degrees Celsius. Resolution 
    4949is 1.0 degree. See the datasheet for details. 
    5050 
  • lm-sensors/trunk/doc/developers/design

    r430 r3000  
    530530As an example, I will here implement our old LM78 access function: 
    531531 
    532 /* The SMBus locks itself, but ISA access must be locked explicitely! 
     532/* The SMBus locks itself, but ISA access must be locked explicitly! 
    533533   We ignore the LM78 BUSY flag at this moment - it could lead to deadlocks, 
    534534   would slow down the LM78 access and should not be necessary. 
  • lm-sensors/trunk/doc/developers/proc

    r2050 r3000  
    123123temp, 
    124124temp[1-4]  3    Temperature max, min or hysteresis, and input value. 
    125                 Floating point values XXX.X or XXX.XX in degrees Celcius. 
     125                Floating point values XXX.X or XXX.XX in degrees Celsius. 
    126126                'temp' is used if there is only one temperature sensor on the 
    127127                chip; for multiple temps. start with 'temp1'. 
  • lm-sensors/trunk/doc/mkpatch

    r1319 r3000  
    6464    them, but before that is done, it changes `#include' lines in the 
    6565    lm_sensors file as specified in INCLUDES 
    66   * It handles several special files, that have to be scanned explicitely 
     66  * It handles several special files, that have to be scanned explicitly 
    6767    to generate diffs to for them 
    6868 
  • lm-sensors/trunk/etc/sensors.conf.eg

    r2984 r3000  
    18901890# note #1: only the LM99 needs this; for a LM89, comment the compute line 
    18911891# out 
    1892 # note #2: there is no way for us to differenciate between a LM89 and a 
     1892# note #2: there is no way for us to differentiate between a LM89 and a 
    18931893# LM99; you have to know what you have; LM99 are frequently found on 
    18941894# graphics cards, most notably nVidia ones 
     
    22662266# 3435 is the thermistor beta. 
    22672267# This assumes that the thermistor forms a resistor divider with a resistor 
    2268 # equal to its nominal value at 25 degres Celcius. If not, change the values. 
     2268# equal to its nominal value at 25 degres Celsius. If not, change the values. 
    22692269# We also assume that you have a working in10 (which is forcibly enabled by 
    22702270# default). If not, use 3.3 instead, but you lose accuracy. 
  • lm-sensors/trunk/kernel/chips/adm1024.c

    r2867 r3000  
    230230#define ADM1024_SYSCTL_FAN1 1101        /* Rotations/min */ 
    231231#define ADM1024_SYSCTL_FAN2 1102 
    232 #define ADM1024_SYSCTL_TEMP 1250        /* Degrees Celcius * 100 */ 
    233 #define ADM1024_SYSCTL_TEMP1 1290       /* Degrees Celcius */ 
    234 #define ADM1024_SYSCTL_TEMP2 1295       /* Degrees Celcius */ 
     232#define ADM1024_SYSCTL_TEMP 1250        /* Degrees Celsius * 100 */ 
     233#define ADM1024_SYSCTL_TEMP1 1290       /* Degrees Celsius */ 
     234#define ADM1024_SYSCTL_TEMP2 1295       /* Degrees Celsius */ 
    235235#define ADM1024_SYSCTL_FAN_DIV 2000     /* 1, 2, 4 or 8 */ 
    236236#define ADM1024_SYSCTL_ALARMS 2001      /* bitvector */ 
  • lm-sensors/trunk/kernel/chips/adm1025.c

    r2867 r3000  
    175175#define ADM1025_SYSCTL_IN5     1005 
    176176 
    177 #define ADM1025_SYSCTL_RTEMP   1250 /* Degrees Celcius * 10 */ 
     177#define ADM1025_SYSCTL_RTEMP   1250 /* Degrees Celsius * 10 */ 
    178178#define ADM1025_SYSCTL_TEMP    1251 
    179179 
  • lm-sensors/trunk/kernel/chips/adm9240.c

    r2867 r3000  
    229229#define ADM9240_SYSCTL_FAN1 1101        /* Rotations/min */ 
    230230#define ADM9240_SYSCTL_FAN2 1102 
    231 #define ADM9240_SYSCTL_TEMP 1250        /* Degrees Celcius * 100 */ 
     231#define ADM9240_SYSCTL_TEMP 1250        /* Degrees Celsius * 100 */ 
    232232#define ADM9240_SYSCTL_FAN_DIV 2000     /* 1, 2, 4 or 8 */ 
    233233#define ADM9240_SYSCTL_ALARMS 2001      /* bitvector */ 
  • lm-sensors/trunk/kernel/chips/asb100.c

    r2837 r3000  
    267267#define ASB100_SYSCTL_FAN3      1103 
    268268 
    269 #define ASB100_SYSCTL_TEMP1     1200    /* Degrees Celcius * 10 */ 
     269#define ASB100_SYSCTL_TEMP1     1200    /* Degrees Celsius * 10 */ 
    270270#define ASB100_SYSCTL_TEMP2     1201 
    271271#define ASB100_SYSCTL_TEMP3     1202 
  • lm-sensors/trunk/kernel/chips/ds1621.c

    r2994 r3000  
    125125 
    126126/* -- SENSORS SYSCTL START -- */ 
    127 #define DS1621_SYSCTL_TEMP 1200 /* Degrees Celcius * 10 */ 
     127#define DS1621_SYSCTL_TEMP 1200 /* Degrees Celsius * 10 */ 
    128128#define DS1621_SYSCTL_ALARMS 2001       /* bitvector */ 
    129129#define DS1621_ALARM_TEMP_HIGH 0x40 
  • lm-sensors/trunk/kernel/chips/gl518sm.c

    r2867 r3000  
    190190#define GL518_SYSCTL_FAN1 1101  /* RPM */ 
    191191#define GL518_SYSCTL_FAN2 1102 
    192 #define GL518_SYSCTL_TEMP 1200  /* Degrees Celcius * 10 */ 
     192#define GL518_SYSCTL_TEMP 1200  /* Degrees Celsius * 10 */ 
    193193#define GL518_SYSCTL_FAN_DIV 2000       /* 1, 2, 4 or 8 */ 
    194194#define GL518_SYSCTL_ALARMS 2001        /* bitvector */ 
  • lm-sensors/trunk/kernel/chips/gl520sm.c

    r2867 r3000  
    186186#define GL520_SYSCTL_FAN1 1101  /* RPM */ 
    187187#define GL520_SYSCTL_FAN2 1102 
    188 #define GL520_SYSCTL_TEMP1 1200 /* Degrees Celcius * 10 */ 
    189 #define GL520_SYSCTL_TEMP2 1201 /* Degrees Celcius * 10 */ 
     188#define GL520_SYSCTL_TEMP1 1200 /* Degrees Celsius * 10 */ 
     189#define GL520_SYSCTL_TEMP2 1201 /* Degrees Celsius * 10 */ 
    190190#define GL520_SYSCTL_VID 1300 
    191191#define GL520_SYSCTL_FAN_DIV 2000       /* 1, 2, 4 or 8 */ 
  • lm-sensors/trunk/kernel/chips/it87.c

    r2994 r3000  
    309309#define IT87_SYSCTL_FAN2 1102 
    310310#define IT87_SYSCTL_FAN3 1103 
    311 #define IT87_SYSCTL_TEMP1 1200  /* Degrees Celcius * 10 */ 
    312 #define IT87_SYSCTL_TEMP2 1201  /* Degrees Celcius * 10 */ 
    313 #define IT87_SYSCTL_TEMP3 1202  /* Degrees Celcius * 10 */ 
     311#define IT87_SYSCTL_TEMP1 1200  /* Degrees Celsius * 10 */ 
     312#define IT87_SYSCTL_TEMP2 1201  /* Degrees Celsius * 10 */ 
     313#define IT87_SYSCTL_TEMP3 1202  /* Degrees Celsius * 10 */ 
    314314#define IT87_SYSCTL_VID 1300    /* Volts * 100 */ 
    315315#define IT87_SYSCTL_FAN_DIV 2000        /* 1, 2, 4 or 8 */ 
  • lm-sensors/trunk/kernel/chips/lm75.c

    r2917 r3000  
    8080/* -- SENSORS SYSCTL START -- */ 
    8181 
    82 #define LM75_SYSCTL_TEMP 1200   /* Degrees Celcius * 10 */ 
     82#define LM75_SYSCTL_TEMP 1200   /* Degrees Celsius * 10 */ 
    8383 
    8484/* -- SENSORS SYSCTL END -- */ 
  • lm-sensors/trunk/kernel/chips/lm78.c

    r2994 r3000  
    186186#define LM78_SYSCTL_FAN2 1102 
    187187#define LM78_SYSCTL_FAN3 1103 
    188 #define LM78_SYSCTL_TEMP 1200   /* Degrees Celcius * 10 */ 
     188#define LM78_SYSCTL_TEMP 1200   /* Degrees Celsius * 10 */ 
    189189#define LM78_SYSCTL_VID 1300    /* Volts * 100 */ 
    190190#define LM78_SYSCTL_FAN_DIV 2000        /* 1, 2, 4 or 8 */ 
  • lm-sensors/trunk/kernel/chips/lm80.c

    r2948 r3000  
    174174#define LM80_SYSCTL_FAN1 1101   /* Rotations/min */ 
    175175#define LM80_SYSCTL_FAN2 1102 
    176 #define LM80_SYSCTL_TEMP 1250   /* Degrees Celcius * 100 */ 
     176#define LM80_SYSCTL_TEMP 1250   /* Degrees Celsius * 100 */ 
    177177#define LM80_SYSCTL_FAN_DIV 2000        /* 1, 2, 4 or 8 */ 
    178178#define LM80_SYSCTL_ALARMS 2001 /* bitvector */ 
  • lm-sensors/trunk/kernel/chips/lm87.c

    r2867 r3000  
    270270#define LM87_SYSCTL_FAN1       1102 
    271271#define LM87_SYSCTL_FAN2       1103 
    272 #define LM87_SYSCTL_TEMP1      1250 /* Degrees Celcius * 10 */ 
    273 #define LM87_SYSCTL_TEMP2      1251 /* Degrees Celcius * 10 */ 
    274 #define LM87_SYSCTL_TEMP3      1252 /* Degrees Celcius * 10 */ 
     272#define LM87_SYSCTL_TEMP1      1250 /* Degrees Celsius * 10 */ 
     273#define LM87_SYSCTL_TEMP2      1251 /* Degrees Celsius * 10 */ 
     274#define LM87_SYSCTL_TEMP3      1252 /* Degrees Celsius * 10 */ 
    275275#define LM87_SYSCTL_FAN_DIV    2000 /* 1, 2, 4 or 8 */ 
    276276#define LM87_SYSCTL_ALARMS     2001 /* bitvector */ 
  • lm-sensors/trunk/kernel/chips/lm93.c

    r2924 r3000  
    9696#define LM93_SYSCTL_IN16                        1016 
    9797 
    98 /* degrees celcius * 10 */ 
     98/* degrees Celsius * 10 */ 
    9999#define LM93_SYSCTL_TEMP1                       1101 
    100100#define LM93_SYSCTL_TEMP2                       1102 
     
    122122#define LM93_SYSCTL_TEMP3_AUTO_PWM_MIN          1153 
    123123 
    124 /* degrees celcius * 10 */ 
     124/* degrees Celsius * 10 */ 
    125125#define LM93_SYSCTL_TEMP1_AUTO_OFFSET_HYST      1161 
    126126#define LM93_SYSCTL_TEMP2_AUTO_OFFSET_HYST      1162 
  • lm-sensors/trunk/kernel/chips/maxilife.c

    r2867 r3000  
    324324#define MAXI_SYSCTL_FAN3   1103 /* Rotations/min */ 
    325325#define MAXI_SYSCTL_FAN4   1104 /* Rotations/min */ 
    326 #define MAXI_SYSCTL_TEMP1  1201 /* Degrees Celcius */ 
    327 #define MAXI_SYSCTL_TEMP2  1202 /* Degrees Celcius */ 
    328 #define MAXI_SYSCTL_TEMP3  1203 /* Degrees Celcius */ 
    329 #define MAXI_SYSCTL_TEMP4  1204 /* Degrees Celcius */ 
    330 #define MAXI_SYSCTL_TEMP5  1205 /* Degrees Celcius */ 
    331 #define MAXI_SYSCTL_TEMP6  1206 /* Degrees Celcius */ 
     326#define MAXI_SYSCTL_TEMP1  1201 /* Degrees Celsius */ 
     327#define MAXI_SYSCTL_TEMP2  1202 /* Degrees Celsius */ 
     328#define MAXI_SYSCTL_TEMP3  1203 /* Degrees Celsius */ 
     329#define MAXI_SYSCTL_TEMP4  1204 /* Degrees Celsius */ 
     330#define MAXI_SYSCTL_TEMP5  1205 /* Degrees Celsius */ 
     331#define MAXI_SYSCTL_TEMP6  1206 /* Degrees Celsius */ 
    332332#define MAXI_SYSCTL_PLL    1301 /* MHz */ 
    333333#define MAXI_SYSCTL_VID1   1401 /* Volts / 6.337, for nba just Volts */ 
  • lm-sensors/trunk/kernel/chips/mtp008.c

    r2867 r3000  
    273273#define MTP008_SYSCTL_FAN2      1102 
    274274#define MTP008_SYSCTL_FAN3      1103 
    275 #define MTP008_SYSCTL_TEMP1     1200    /* Degrees Celcius * 10 */ 
    276 #define MTP008_SYSCTL_TEMP2     1201    /* Degrees Celcius * 10 */ 
    277 #define MTP008_SYSCTL_TEMP3     1202    /* Degrees Celcius * 10 */ 
     275#define MTP008_SYSCTL_TEMP1     1200    /* Degrees Celsius * 10 */ 
     276#define MTP008_SYSCTL_TEMP2     1201    /* Degrees Celsius * 10 */ 
     277#define MTP008_SYSCTL_TEMP3     1202    /* Degrees Celsius * 10 */ 
    278278#define MTP008_SYSCTL_VID       1300    /* Volts * 100 */ 
    279279#define MTP008_SYSCTL_PWM1      1401 
  • lm-sensors/trunk/kernel/chips/pc87360.c

    r2949 r3000  
    328328#define PC87365_STATUS_IN_MAX           0x04 
    329329 
    330 #define PC87365_SYSCTL_TEMP1            3101 /* degrees Celcius */ 
     330#define PC87365_SYSCTL_TEMP1            3101 /* degrees Celsius */ 
    331331#define PC87365_SYSCTL_TEMP2            3102 
    332332#define PC87365_SYSCTL_TEMP3            3103 /* not for PC87365 */ 
  • lm-sensors/trunk/kernel/chips/sis5595.c

    r2868 r3000  
    235235#define SIS5595_SYSCTL_FAN1 1101        /* Rotations/min */ 
    236236#define SIS5595_SYSCTL_FAN2 1102 
    237 #define SIS5595_SYSCTL_TEMP 1200        /* Degrees Celcius * 10 */ 
     237#define SIS5595_SYSCTL_TEMP 1200        /* Degrees Celsius * 10 */ 
    238238#define SIS5595_SYSCTL_FAN_DIV 2000     /* 1, 2, 4 or 8 */ 
    239239#define SIS5595_SYSCTL_ALARMS 2001      /* bitvector */ 
  • lm-sensors/trunk/kernel/chips/thmc50.c

    r2867 r3000  
    122122/* -- SENSORS SYSCTL START -- */ 
    123123 
    124 #define THMC50_SYSCTL_TEMP 1200 /* Degrees Celcius */ 
    125 #define THMC50_SYSCTL_REMOTE_TEMP 1201  /* Degrees Celcius */ 
     124#define THMC50_SYSCTL_TEMP 1200 /* Degrees Celsius */ 
     125#define THMC50_SYSCTL_REMOTE_TEMP 1201  /* Degrees Celsius */ 
    126126#define THMC50_SYSCTL_INTER 1202 
    127127#define THMC50_SYSCTL_INTER_MASK 1203 
  • lm-sensors/trunk/kernel/chips/w83627hf.c

    r2997 r3000  
    384384#define W83781D_SYSCTL_FAN2 1102 
    385385#define W83781D_SYSCTL_FAN3 1103 
    386 #define W83781D_SYSCTL_TEMP1 1200       /* Degrees Celcius * 10 */ 
    387 #define W83781D_SYSCTL_TEMP2 1201       /* Degrees Celcius * 10 */ 
    388 #define W83781D_SYSCTL_TEMP3 1202       /* Degrees Celcius * 10 */ 
     386#define W83781D_SYSCTL_TEMP1 1200       /* Degrees Celsius * 10 */ 
     387#define W83781D_SYSCTL_TEMP2 1201       /* Degrees Celsius * 10 */ 
     388#define W83781D_SYSCTL_TEMP3 1202       /* Degrees Celsius * 10 */ 
    389389#define W83781D_SYSCTL_VID 1300         /* Volts * 1000 */ 
    390390#define W83781D_SYSCTL_VRM 1301 
  • lm-sensors/trunk/kernel/chips/w83781d.c

    r2999 r3000  
    353353#define W83781D_SYSCTL_FAN5 1105 
    354354 
    355 #define W83781D_SYSCTL_TEMP1 1200       /* Degrees Celcius * 10 */ 
    356 #define W83781D_SYSCTL_TEMP2 1201       /* Degrees Celcius * 10 */ 
    357 #define W83781D_SYSCTL_TEMP3 1202       /* Degrees Celcius * 10 */ 
     355#define W83781D_SYSCTL_TEMP1 1200       /* Degrees Celsius * 10 */ 
     356#define W83781D_SYSCTL_TEMP2 1201       /* Degrees Celsius * 10 */ 
     357#define W83781D_SYSCTL_TEMP3 1202       /* Degrees Celsius * 10 */ 
    358358#define W83781D_SYSCTL_VID 1300         /* Volts * 1000 */ 
    359359#define W83781D_SYSCTL_VRM 1301 
  • lm-sensors/trunk/lib/sensors.conf.5

    r2456 r3000  
    357357class members. A specific statement for a class member feature always 
    358358overrides the general class setting, though. This means that you can't 
    359 override the class name feature explicitely. 
     359override the class name feature explicitly. 
    360360 
    361361A simple example will explain this better. The