Changeset 3007 for lm-sensors/trunk/doc/chips/vt1211
- Timestamp:
- 05/24/05 23:26:22 (7 years ago)
- Files:
-
- 1 modified
-
lm-sensors/trunk/doc/chips/vt1211 (modified) (1 diff)
Legend:
- Unmodified
- Added
- Removed
-
lm-sensors/trunk/doc/chips/vt1211
r1678 r3007 50 50 Temperatures will read a really low number if set for voltage. 51 51 52 F ANrotation speeds are reported in RPM (rotations per minute). An alarm is53 triggered if the rotation speed has dropped below a programmable limit. F AN52 Fan rotation speeds are reported in RPM (rotations per minute). An alarm is 53 triggered if the rotation speed has dropped below a programmable limit. Fan 54 54 readings can be divided by a programmable divider (1, 2, 4 or 8) to give 55 the readings more range or accuracy. This is important because some FANs 56 report only one 'tick' each rotation, while others report two - making 57 all readings twice as high. Not all RPM values can accurately be represented, 58 so some rounding is done. With a divider of 2, the lowest representable 59 value is around 2600 RPM. 55 the readings more range or accuracy. Not all RPM values can accurately be 56 represented, so some rounding is done. With a divider of 2, the lowest 57 representable value is around 2600 RPM. 60 58 61 59 PWM values are from 0 to 255. The first value in the /proc entry is
