  • lm-sensors/branches/lm-sensors-3.0.0/etc/sensors.conf.eg

    r4600 r4685  
    3434# A 'chip' line specifies what the following 'label', 'compute', 'set' and 
    3535# 'ignore' lines refer to. In this case, until the 
    36 # next 'chip' line, everything refers to all lm78, lm78-j and lm79 
     36# next 'chip' line, everything refers to all lm78 and lm79 
    3737# chips. Other examples are *-isa-* for everything on the ISA bus, and 
    38 # lm78-j-i2c-*-4e for all lm78-j chips on address 0x4e of any I2C bus. 
     38# lm78-i2c-*-4e for all lm78 chips on address 0x4e of any I2C bus. 
    3939# 
    4040# If more chip statements match a specific chip, they are all considered. 
     
    4444# chips on a non-ISA bus. 
    4545# 
    46 #       chip "lm78-*" "lm78-j-*" "lm79-*" 
     46#       chip "lm78-*" "lm79-*" 
    4747# 
    4848# 
     
    275275 
    276276 
    277 chip "lm78-*" "lm78-j-*" "lm79-*" "w83781d-*" 
     277chip "lm78-*" "lm79-*" "w83781d-*" 
    278278 
    279279# These are as advised in the LM78 and LM79 data sheets, and used on almost 
     
    10521052#    set temp_os_hyst  57 
    10531053#    set temp_os_max   62 
    1054  
    1055  
    1056 chip "maxilife-cg-*" "maxilife-co-*" "maxilife-as-*" 
    1057  
    1058    label fan1  "HDD Fan" 
    1059    label fan2  "PCI Fan" 
    1060    label fan3  "CPU Fan" 
    1061    ignore fan4 
    1062  
    1063    label temp2 "PCI Temp" 
    1064    label temp4 "HDD Temp" 
    1065    label temp5 "CPU Temp" 
    1066    ignore temp6 
    1067  
    1068    label vid1  "V+12" 
    1069    ignore vid5 
    1070  
    1071 # vid1 need to be scaled by 6.337 other voltages 
    1072 # require no scaling 
    1073  
    1074    compute vid1 6.337*@ , @/6.337 
    1075  
    1076  
    1077 chip "maxilife-cg-*" 
    1078  
    1079    ignore temp1 
    1080    label temp3  "BX Temp" 
    1081  
    1082    label vid2   "Vcpu1" 
    1083    label vid3   "Vcpu2" 
    1084    ignore vid4 
    1085  
    1086  
    1087 chip "maxilife-co-*" 
    1088  
    1089    label temp1  "CPU 1 Temp" 
    1090    label temp3  "CPU 2 Temp" 
    1091  
    1092    label vid2   "Vcpu1" 
    1093    label vid3   "Vcpu2" 
    1094    label vid4   "VcacheL2" 
    1095  
    1096  
    1097 chip "maxilife-as-*" 
    1098  
    1099    ignore temp1 
    1100    ignore temp3 
    1101  
    1102    label vid2   "Vcpu" 
    1103    ignore vid3 
    1104    ignore vid4 
    1105  
    1106  
    1107 chip "maxilife-nba-*" 
    1108  
    1109    label fan1  "CPU Fan" 
    1110    label fan2  "PCI Fan" 
    1111    label fan3  "HDD Fan" 
    1112    label fan4  "Heat Sink Fan" 
    1113  
    1114    label temp1  "CPU 1 Temp" 
    1115    label temp2  "CPU 2 Temp" 
    1116    label temp3  "PCI/Ambient Temp" 
    1117    label temp4  "HDD Temp" 
    1118    label temp5  "Motherboard Temp" 
    1119    label temp6  "CPU Reference Temp" 
    1120  
    1121    label vid1  "V+12" 
    1122    label vid2  "Vcpu1" 
    1123    label vid3  "Vcpu2" 
    1124    label vid4  "VcacheL2" 
    1125    label vid5  "V-12" 