Ticket #1901 (closed task)

Opened 8 years ago

wrong alarm by sensors (Examined/Solved - 2.9.0 on 2.4.26 and 2.9.1-CVS-050309 on 2.4.26)

Reported by: contact Owned by: somebody
Priority: minor Milestone:
Component: interface Version:
Keywords: Cc:

Description

I am running lm_sensors/i2c (both 2.9.0 and 2.9.1-CVS-050309 on linux-2.4.26).

When I run sensors, it shows me two ALARMs, even when the values for

negative voltage are perfectly inside the tolerance interval.

,--[ output from sensors ]--

it87-isa-0290

Adapter: ISA adapter

Vcore 1: +1.74 V (min = +1.62 V, max = +1.78 V)

Vcore 2: +2.45 V (min = +2.40 V, max = +2.61 V)

+3.3V: +3.25 V (min = +3.14 V, max = +3.46 V)

+5V: +4.97 V (min = +4.74 V, max = +5.24 V)

+12V: +12.28 V (min = +11.40 V, max = +12.60 V)

-12V: -11.74 V (min = -12.60 V, max = -11.41 V) ALARM

-5V: -5.15 V (min = -5.24 V, max = -4.69 V) ALARM

Stdby: +4.89 V (min = +4.74 V, max = +5.24 V)

VBat: +0.00 V

CPU fan: 5357 RPM (min = 2986 RPM, div = 4)

box fan: 2360 RPM (min = 1997 RPM, div = 4)

CPU temp: +50C (low = +15C, high = +60C) sensor = thermistor

M/B temp: +42C (low = +15C, high = +50C) sensor = thermistor

'--[ ]--

I presume, there is something wrong with the settings in

/proc/sys/dev/sensors/it87-isa-0290/alarms.

P.S. Thank you for this program.

--- Swap inN_min and inN_max in /etc/sensors.conf for -5V and -12V. In some cases,

for negative voltages, the min limit is the one nearest from 0, not most

negative value. (Technically, it depends whether inverting amplifier or

reference voltage is used.)

Khali 2005-03-10